I100

Cost-effective Double Sheet Detection with dual head sensors.

  Datasheet I100

Applications

Cost-effective Double Sheet Detection with dual head sensors

Features

  • Dual head sensors (transmitter / receiver), inductive
  • Non-contact double sheet detection of
    - Ferrous materials .05 - 4 mm (.002in. - .16in.).(single sheet thickness)
    - Non-ferrous materials .05 - 12 mm ( .002in. - .50in.), single sheet thickness
  • Suitable for fluttering sheets
  • Easy setup by key operation or via control input
  • LCD display for visualization of nominal / current values, operational / error messages, key allocation
  • Compact enclosure for DIN-rail mounting, protection class IP00

Device Variations

  • I100: Compact enclosure for DIN rail mounting, protection class IP00
  • I100-S: Aluminum enclosure for mounting, pluggable connections, protection class IP54

Sensors

Technology:Inductive transmission process
Sensor:S/E34S/E75
Meas. area:

Steel magn. [FE]0.05 ... 1 (1.5) mm0.1 ... 3 (4) mm
Aluminum [NF]0.2 ... 6 mm3 ... 5 (15) mm
Stainl. steel aust.[NE]----
Non-metals----
Air gap:10 ... 40 mm30 ... 60 mm
Particularity:Sensor distance up to 80 mmSensor distance up to 80 mm
Meas. time:18 ... 75 ms18 ... 75 ms

Technical Data

Applications:Cost-effective Double Sheet Detection with dual head sensors.
Material + Thickness:
Steel magn. [FE]: 0.05 ... 3 (4) mm

Aluminum [NF]: 0.2 ... 5 (15) mm
Meas. method:Sensorpaare (Sender / Empfänger)
Function principle:Induktives Transmissionsverfahren
Programs:1 measurement program, in memory storage
Switching threshold:85% and 115% of nominal value
Particularity:Suitable for fluttering sheets.

Easy setup by key operation or via control input.

LCD display for visualization of nominal / current values, operational / error messages, key allocation.